ES-2378 Rev.8

IT40SRE

Tower Light Series

ETHERNET TOWER LIGHT

(small size, 40 mm dia., Modbus/TCP, 1 - 5 layers)
Functions & Features
• Lighting, blinking and buzzing available with PLC or PC via Modbus/TCP.

MODEL: IT40SRE-[1][2][3][4][5][6]D1-[7][8]

ORDERING INFORMATION

• Code number: IT40SRE-[1][2][3][4][5][6]D1-[7][8]
Specify a code from below for each of [1] through [8].
  (e.g. IT40SRE-5RYGBWD1-R/Q)
• Specify the specification for option code /Q
  (e.g. /C01)

[1] LAMP LAYERS

1: 1 layer
2: 2 layers
3: 3 layers
4: 4 layers
5: 5 layers

[2] LAMP 1 COLOR

(1st layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White

[3] LAMP 2 COLOR

(2nd layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 2 - 5)

[4] LAMP 3 COLOR

(3rd layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 3 - 5)

[5] LAMP 4 COLOR

(4th layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 4 - 5)

[6] LAMP 5 COLOR

R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 5)
* Select "None" option for the layers other than the selected.

MOUNTING

D: Direct mounting

DESIGN TYPE

1: Type 1
(refer to outline dimensions)

[7] POWER INPUT

AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

[8] OPTIONS

blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q

COATING (For the detail, refer to our web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

RELATED PRODUCTS

• LAN cable (model: ITCA)
• Mounting Pole (model: ITPL, ITB, ITP, ITW and ITS)
• Mounting Adapter (model: ITAD1, ITAM, ITAR and ITAW)
• PC configurator software (model: ITCFG)
Functions are configurable using the PC Configurator Software.
Downloadable at our web site.
Access to 192.168.0.1, the factory default setting, to set the device first time.

GENERAL SPECIFICATIONS

Degree of protection: IP 65, vertical mounting only (bottom connectors excluded)
Connection
  Power
:UL1007 AWG20
  Network: RJ-45 Modular Jack
Housing material: Flame-resistant resin
Lens
: Flame-resistant resin (transparent)
Isolation: Network to power input to FE1 (Functional Earth)
DIP SW Setting: Frequency of lamp blinking and buzzing discontinuance, buzzing volume level, output at connection failed and IP address (refer to the instruction manual)
Lamp: Red, amber, green, blue and white LEDs
on/blinking (approx. 2 Hz, 10 Hz)
Status indicator LEDs: Power, Run
(Refer to the insruction manual)
Buzzing: Approx. 3.3 kHz
  Interval: continuous/intermittent (approx. 2 Hz, 10 Hz)

COMMUNICATION

Communication Standard: IEEE 802.3u
Transmission: 10BASE-T, 100BASE-TX
Baud rate: 10/100 Mbps (Auto Negotiation function)
Protocol: Modbus/TCP
Data: RTU (Binary)
Max. number of socket connections: 2
Transmission media: 10BASE-T (STP, Category 5) 100BASE-TX (STP, Category 5e)
Max. length of fieldbus segment: 100 meters
IP address: 192.168.0.1 (factory setting);
Selectable with PC Configurator Software
(model: ITCFG)
Port No.: 502
Ethernet indicator LED: Link, Link100, COL

INSTALLATION

Power Consumption
AC:
Approx. 5.5 VA at 100 V with max. load
Approx. 7 VA at 200 V with max. load
Approx. 8 VA at 240 V with max. load
DC: Approx. 3 W
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas
Mounting: Direct mounting
Mounting direction: Vertical
Weight: Approx. 650 g (1.43 lb)

PERFORMANCE

Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(network to power to FE1)

STANDARDS & APPROVALS

Refer to the manuals to comply with the standards.
EU conformity:
EMC Directive 
  EN 60947-5-1
Low Voltage Directive 
 EN 60947-5-1
  ・24 V DC power
   Installation Category III
   Pollution Degree 3
  ・100 – 240 V AC power
   Installation Category II
   Pollution Degree 2
  Network to power: Reinforced insulation (300 V)
RoHS Directive

EXTERNAL VIEW

EXTERNAL DIMENSIONS unit: mm

MOUNTING REQUIREMENTS unit: mm