ES-5466 Rev.4

M8LCS

Dual Output Super-mini Signal Conditioners Pico-M Series

STRAIN GAUGE CONVERTER

Functions & Features
• Provides two DC output signals proportional to a bridge type strain gauge utilized in load cells, pressure transducers
• Supplies required excitation voltage
• Drives strain gauges of various bridge resistance and rated output voltage
• Excitation selectable among 2.5 V, 5 V or 10 V
• Wide-range adjustment: 0 – 60 % for zero, 40 – 100 % for span
• Space-saving, easy-to-maintain, multi-channel installation base

MODEL: M8LCS-[1][2][3]-R

ORDERING INFORMATION

• Code number: M8LCS-[1][2][3]-R
Specify a code from below for each of [1] through [3].
  (e.g. M8LCS-226A-R)
• Special input strain gauge range (For code 0)
• Special excitation range (For code 0)

[1] INPUT STRAIN GAUGE

1: 1 mV/V
12: 1.25 mV/V
15: 1.5 mV/V
2: 2 mV/V
3: 3 mV/V
4: 4 mV/V
5: 5 mV/V
6: 10 mV/V
7: 20 mV/V
0: Specify (See INPUT SPECIFICATIONS)

[2] EXCITATION

1: 2.5 V
2: 5 V
3: 10 V
0: Specify (See INPUT SPECIFICATIONS)

[3] OUTPUT 1 / OUTPUT 2

6A: 1 – 5 V DC (Load resistance 2500 Ω min.)
    / 4 – 20 mA DC (Load resistance 300 Ω max.)
44: 0 – 10 V DC (Load Resistance 5000 Ω min.)
    / 0 – 10 V DC (Load Resistance 5000 Ω min.)
55: 0 – 5 V DC  (Load resistance 2500 Ω min.)
    / 0 – 5 V DC  (Load resistance 2500 Ω min.)
66: 1 – 5 V DC (Load resistance 2500 Ω min.)
    / 1 – 5 V DC (Load resistance 2500 Ω min.)

POWER INPUT

DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

RELATED PRODUCTS

• Installation Base or Single Mount Base Socket (model: M8BSx)
This unit must be mounted on dedicated base or socket.

GENERAL SPECIFICATIONS

Construction: Plug-in
Mounting screw: M3 screw (torque 0.3 N·m)
Housing material: Flame-resistant resin (black)
Power supply: Via the Installation Base terminals
(model: M8BSx)
Isolation: Input to output 1 to output 2 to power
Zero adjustment: 0 – 60 % (front)
Span adjustment: 100 – 40 % (front)

INPUT SPECIFICATIONS

■ Input: Bridge voltage from load cells
Permissible leadwire resistance: Strain Gauge Composite Resistance × 0.25
• Strain Gauge
Rated output from strain gauge: 1 – 20 mV/V;
M8LCS input voltage -100 –+100 mV;
Input to the M8LCS must be over 5 mV.
(The input must be over 10 mV when Code 0 is selected for the strain gauge and/or the excitation.)
• Excitation: 2 – 10 V
Maximum current: 45 mA

INSTALLATION

Current consumption: Approx. 60 mA (80 mA for current output)
Operating temperature: 0 to 55°C (32 to 131°F)
Operating humidity: 30 to 95 %RH (non-condensing)
Mounting: Installation Base (model: M8BSx)
Weight: 70 g (2.5 oz)

PERFORMANCE in percentage of span

Accuracy: ±0.1 % (input ≥ 5 mV)
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F) (input ≥ 5 mV)
Response time: ≤ 0.2 sec. (0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength:
1500 V AC @1 minute (input to output 1 or output 2 or power to ground)
500 V AC @1 minute (output 1 to output 2 to power)
SWC test: ANSI/IEEE-C37.90.1-1989

FRONT VIEW

Span adjustment (sensitivity adjustment)
40 – 100 % of input span
Zero adjustment (tare adjustment)
0 – 60 % of input span

EXTERNAL DIMENSIONS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM