ES-5986 Rev.3
M1EXS-2
2 Channel Super-mini Signal Conditioners
with Display M1E-2 Series
SELF-SYNCH TRANSMITTER
(2 channels, PC programmable)
Functions & Features
• Converts position signals from a self-synchronizing motor into a DC signal proportional to the rotating shaft position
• 2 channels
• Adjustments with the front buttons
• OEL display with good visibility
• Linearization available for each channel (111 points)
Typical Applications
• Position indicator using self-synch
• Tank gauge
• Sounding level meter
MODEL: M1EXS-2–K3[1]
ORDERING INFORMATION
• Code number: M1EXS-2-K3[1]
Specify a code from below for [1].
(e.g. M1EXS-2-K3/Q)
• Specify the specification for option code /Q
(e.g. /C01/SET)
NO. OF CHANNELS
2
: 2 channels
INPUT
Self-synch signal
OUTPUT – Field-selectable
◆ DC Output
•
Current output
: 0 - 20 mA DC
• Voltage output
: -5 - +5 V DC
• Voltage output
: -10 - +10 V DC
POWER INPUT
AC Power
K3
: 100 – 120V AC
(Operational voltage range 85 - 132 V, 47 - 66 Hz)
[1] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
EX-FACTORY SETTING
/SET
: Preset according to the Ordering Information Sheet
(No. ESU-5986)
RELATED PRODUCTS
• Installation base (model: M1E-BS2)
• M1E configurator software (model: M1ECFG)
Downloadable at our web site.
A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual (EM-5981) for the M1E configurator for applicable cable types.
GENERAL SPECIFICATIONS
Construction
: Plug-in
Connection
• Connected to base with connector
• Base
M2.6 screw terminals (torque: 0.5 N·m)
Applicable solderless terminal size (M3)
Screw terminal
: Nickel-plated steel
Housing material
: Flame-resistant resin (black)
Isolation
: Ch1.input to ch2.input to Ch1.output to ch2.output to power
Overrange output
: Approx. -5 to +105 % (Not available for current output not greater than 0 mA)
Output zero fine adj. range
: -5 to +5% (front button)
Output span fine adj. range
: 95 to 105% (front button)
Configuration
: Program with front buttons or Via PC.
Programmable features include
: Refer to the parameter list.
Configurator connection
: 2.5 dia. miniature jack;
RS-232-C level
■Recommended solderless terminal size - M3 (unit: mm)
DISPLAY
Display functions
: Displays and sets measured range, engineering unit
Display size
: Approx. 15.6 × 20.8 mm (0.61” × 0.82”)
Number of pixels
: 68 × 95 (horizontal × vertical)
Character color
: Yellow
Display life
: Approx. 50000 hours
(Expected time for the Display brightness to be reduced to 50 % when the Display is used continuously with brightness setting 2 in 25 ℃)
Display type
: OEL display
Display digit
: Negative 5 digits, positive 6 digits (-99999 to 999999)
Decimal point position
: Selectable
INPUT SPECIFICATIONS
Measurement range
: 0 – 359.99° (deg)
Minimum span
: 60° (deg)
Input resistance
: 1 MΩ min.
Rated input voltage
: 30 – 90 V AC
OUTPUT SPECIFICATIONS
■ DC Current
Output range
: 0 – 20 mA DC
Conformance range
: 0 – 21mA DC
Minimum span
: 1 mA
Load resistance
: Output drive 15 V max.
(e.g. 4 – 20 mA: 750 Ω [15 V ÷ 20 mA])
(Not available to output less than 0 mA, output range may not be extended to -5 %)
■
DC Voltage
Output range
: -5 - +5 V DC, -10 - +10 V DC
Conformance range
: -5.5 - +5.5 V DC, -11 - +11 V DC
Minimum span
: 250 mV, 1 V
Load resistance
: 200 kΩ min.
INSTALLATION
Power Consumption
•
AC
: ≤ 7 VA
Operating temperature
: -5 to +55°C (23 to 131°F)
Storage temperature
: -5 to +55°C (23 to 131°F)
Operating humidity
: 10 to 85 %RH (non-condensing)
Mounting
: Surface or DIN rail
Weight
: 120 g (0.26 lb) except base
PERFORMANCE
Accuracy
: Input accuracy + output accuracy
input accuracy + (output accuracy × segment gain) when segment gain > 1
See CALCULATION EXAMPLES OF OVERALL ACCURACY.
Inversely proportional to the setting span.
Input accuracy
: ±0.2 % of span or ±0.5°, whichever is greater.
Display accuracy
:
Input display: Input accuracy ±1 digit
Output display: Input accuracy + output accuracy ±1 digit
Output accuracy
: (% of max. output range)
0 - 20 mA: ±0.06 %
-5 - +5 V: ±0.03 %
-10 - +10 V: ±0.03 %
Temp. coefficient (% of max. I/O range)
: ±0.015 %/°C (±0.008 %/°F)
Response time (filter time constant: 0 sec.)
: ≤ 0.5 sec.
(0 – 90 %)
Line voltage effect
: ±0.1 % over voltage range
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute
(Ch1 input to Ch2 input to Ch1 output to Ch2 output to power to ground)
CALCULATION EXAMPLES OF OVERALL ACCURACY
[Example] Input Span 60°, Output Range 0 – 20 mA, Output Setting 4 – 20 mA, Segment Gain 1.5
■
Overall accuracy
• Input Accuracy = Input (60°) × Input Accuracy (0.2 %) = 0.12°
0.12°< 0.5° thus
Input Accuracy = 0.5° ÷ 60° × 100 = 0.83 %
• Output Accuracy = Output Range Span (20 mA) ÷ Output Span Setting (16 mA) × 0.06 % × Segment Gain (1.5) = 0.1125 %
Overall Accuracy = 0.83 + 0.1125 = ±0.9425 %
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
EXTERNAL VIEW
Refer to the operating manual (EM-5986-B) for detailed procedures.
TERMINAL ASSIGNMENTS
* Base does not come with the unit. Please order separately.
PARAMETER LIST
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
MOUNTING REQUIREMENTS unit: mm [inch]
* Mounting requirements for base.