ES-9311 Rev.14
48V
Bargraph Indicators 48 Series
BARGRAPH INDICATOR
Functions & Features
• Displaying a process variable in graphic bargraph of 101 LED segments
• Clear LED
• High-density mounting
MODEL: 48V–[1][2][3][4]-[5]
ORDERING INFORMATION
• Code number: 48V-[1][2][3][4]-[5]
Specify a code from below for each of [1] through [5].
(e.g. 48V-2RRVA-R)
• Special input range (For codes Z & 0)
• Scale (e.g. 0 – 100 %)
[1] BARGRAPHS
1
: Single
2
: Dual
[2] LED COLOR
R
: Red
Y
: Amber
G
: Green
Dual (left/right)
RR
: Red / Red
YY
: Amber / Amber
GG
: Green / Green
RY
: Red / Amber
RG
: Red / Green
YR
: Amber / Red
YG
: Amber / Green
GR
: Green / Red
GY
: Green / Amber
[3] MOUNTING DIRECTION
V
: Vertical
H
: Horizontal
[4] INPUT
Current
A
: 4 – 20 mA DC (Input resistance 10 Ω)
B
: 2 – 10 mA DC (Input resistance 20 Ω)
C
: 1 – 5 mA DC (Input resistance 39 Ω)
D
: 0 – 20 mA DC (Input resistance 10 Ω)
E
: 0 – 16 mA DC (Input resistance 12 Ω)
F
: 0 – 10 mA DC (Input resistance 20 Ω)
G
: 0 – 1 mA DC (Input resistance 200 Ω)
H
: 10 – 50 mA DC (Input resistance 3.9 Ω)
Z
: Specify current (See INPUT SPECIFICATIONS)
Voltage
3
: 0 – 1 V DC (Input resistance 100 kΩ)
4
: 0 – 10 V DC (Input resistance 330 kΩ)
5
: 0 – 5 V DC (Input resistance 250 kΩ)
6
: 1 – 5 V DC (Input resistance 250 kΩ)
0
: Specify voltage (See INPUT SPECIFICATIONS)
[5] POWER INPUT
AC Power
K
: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 63 Hz)
L
: 170 – 264 V AC
(Operational voltage range 170 – 264 V, 47 – 63 Hz)
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±15 %, ripple 10 %p-p max.)
GENERAL SPECIFICATIONS
Construction
: Panel flush mounting
Connection
: M3 screw terminals (torque 0.6 N·m)
Screw terminal
: Chromated brass
Housing material
: ABS resin
Isolation
: Input 1 to input 2 to power
Scale plate
: Aluminium (white scale & characters on black base)
Scale
•
Characters including decimal points
:
Max. 6 charac. (48V-1, vertical mount.)
Max. 4 charac. (48V-2, vertical mount.)
Max. 4 charac. (48V-1, horizontal mount.)
Max. 4 charac. (48V-2, horizontal mount.)
•
Divisions
: 22 – 54.9
•
Engineering unit
:
Max. 8 charac. (48V-1, vertical mount.)
Max. 5 charac. (48V-2, vertical mount.)
Max. 8 charac. (48V-1, horizontal mount.)
Max. 3 charac. (48V-2, horizontal mount.)
If there is only one engineering unit with dual bargraph
type, the position and maximum number of characters
for single type are applied.
Bargraph:
101-segment LED, 100 mm (3.96”) long, 1.5 mm (.06”) wide
INPUT SPECIFICATIONS
■
DC Current
: 0 – 50 mA DC; input resistor incorporated
Minimum span
: 1 mA
0 % input
: 0 mA DC
■
DC Voltage
: 0 – 10 V DC
Minimum span
: 1 V
0 % input
: 0 V DC
INSTALLATION
Power consumption
•
AC
: Approx. 3.5 VA (single) or 5.5 VA (dual)
•
DC
: Approx. 2 W (single) or 4 W (dual)
Operating temperature
: 0 to 50°C (32 to 122°F)
Operating humidity
: 40 to 80 %RH (non-condensing)
Mounting
: Panel flush mounting
Weight
:
290 g (0.64 lb) for 48V-1, DC powered
320 g (0.71 lb) for 48V-1, AC powered
340 g (0.75 lb) for 48V-2, DC powered
370 g (0.82 lb) for 48V-2, AC powered
PERFORMANCE in percentage of span
Accuracy
: ±1 % ±1 digit
Response time
: 0.5 sec.
Insulation resistance
: ≥ 50 MΩ with 500 V DC
(input or power to ground)
Dielectric strength
:
2000 V AC @1 minute (input or power to ground)
1500 V AC @ 1 minute (input to AC power)
500 V AC @ 1 minute (input to DC power)
500 V AC @ 1 minute (input 1 to input 2)
STANDARD SCALE & UNIT EXAMPLES
EXTERNAL VIEW
CONNECTION DIAGRAM
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
PANEL CUTOUT unit: mm