·Some details are not shown. Please refer to specification sheets for all information.

IT60SRE

Tower Light Series

ETHERNET TOWER LIGHT
(small size, 60 mm dia., Modbus/TCP, 1 - 5 layers)

Functions & Features
• Lighting, blinking and buzzing available with PLC or PC via Modbus/TCP.

MODEL: IT60SRE-[1][2][3][4][5][6]D1-[7][8]

ORDERING INFORMATION
• Code number: IT60SRE-[1][2][3][4][5][6]D1-[7][8]
Specify a code from below for each [1] through [8].
 (e.g. IT60SRE-5RYGBWD1-R/Q)
• Specify the specification for option code /Q
 (e.g. /C01)

[1] LAMP LAYERS
1: 1 layer
2: 2 layers
3: 3 layers
4: 4 layers
5: 5 layers

[2] LAMP 1 COLOR
(1st layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White

[3] LAMP 2 COLOR
(2nd layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 2 - 5)

[4] LAMP 3 COLOR
(3rd layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 3 - 5)

[5] LAMP 4 COLOR
(4th layer from the top)
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 4 - 5)

[6] LAMP 5 COLOR
R: Red
Y: Amber
G: Green
B: Blue
W: White
N: None (not available when Lamp Layers selected are 5)
* Select "None" option for the layers other than the selected.

MOUNTING
D: Direct mounting

DESIGN TYPE
1: Type 1
(refer to outline dimensions)

[7] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

[8] OPTIONS
blank: none
/Q: With options (specify the specification)

SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating

RELATED PRODUCTS
• LAN cable (model: ITCA)
• Mounting Pole (model: ITPL)
• Mounting Adapter (model: ITAD1)
• PC configurator software (model: ITCFG)
Functions are configurable using the PC Configurator Software.
Downloadable at M-System’s web site.
Access to 192.168.0.1, the factory default setting, to set the device first time.

GENERAL SPECIFICATIONS
Degree of protection: IP 65, vertical mounting only (bottom connectors excluded)
Connection
  Power
:UL1007 AWG20
  Network: RJ-45 Modular Jack
Housing material: Flame-resistant resin
Lens
: Flame-resistant resin (transparent)
Isolation: Network to power input to FE1 (Functional Earth)
DIP SW Setting: Frequency of lamp blinking and buzzing discontinuance, buzzing volume level, output at connection failed and IP address (refer to the instruction manual)
Lamp: Red, amber, green, blue and white LEDs
on/blinking (approx. 2 Hz, 10 Hz)
Indicator LEDs: Power, Run
(Refer to the insruction manual)
Buzzing: Approx. 3.3 kHz
  Interval: continuous/intermittent (approx. 2 Hz, 10 Hz)

COMMUNICATION
Communication Standard: IEEE 802.3u
Transmission: 10BASE-T, 100BASE-TX
Baud rate: 10/100 Mbps (Auto Negotiation function)
Protocol: Modbus/TCP
Data: RTU (Binary)
Max. number of socket connections: 2
Transmission media: 10BASE-T (STP, Category 5) 100BASE-TX (STP, Category 5e)
Max. length of fieldbus segment: 100 meters
IP address: 192.168.0.1 (factory setting);
Selectable with PC Configurator Software
(model: ITCFG)
Port No.: 502
Ethernet indicator LED: Link, Link100, COL

INSTALLATION
Power Consumption
AC:
Approx. 7.5 VA at 100 V with max. load
Approx. 10 VA at 200 V with max. load
Approx. 11 VA at 240 V with max. load
DC: Approx. 5 W
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas
Mounting: Direct mounting
Mounting direction: Vertical
Weight: 750 g (1.65 lb)

PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(network to power to FE1)

STANDARDS & APPROVALS
Refer to the manuals to comply with the standards.
EU conformity:
EMC Directive 
  EN 60947-5-1
Low Voltage Directive 
 EN 60947-5-1
  ・24 V DC power
   Installation Category III
   Pollution Degree 3
  ・100 – 240 V AC power
   Installation Category II
   Pollution Degree 2
  Network to power: Reinforced insulation (300 V)
RoHS Directive
  EN 50581

EXTERNAL VIEW

DIMENSIONS unit: mm

MOUNTING REQUIREMENTS unit: mm

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

MG Co., Ltd.