·Some details are not shown. Please refer to specification sheets for all information.
IT60SRE
Tower Light Series
ETHERNET TOWER LIGHT
(small size, 60 mm dia., Modbus/TCP, 1 - 5 layers)
Functions & Features
• Lighting, blinking and buzzing available with PLC or PC via Modbus/TCP.
MODEL: IT60SRE-[1][2][3][4][5][6]D1-[7][8]
ORDERING INFORMATION
• Code number: IT60SRE-[1][2][3][4][5][6]D1-[7][8]
Specify a code from below for each [1] through [8].
(e.g. IT60SRE-5RYGBWD1-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] LAMP LAYERS
1
: 1 layer
2
: 2 layers
3
: 3 layers
4
: 4 layers
5
: 5 layers
[2] LAMP 1 COLOR
(1st layer from the top)
R
: Red
Y
: Amber
G
: Green
B
: Blue
W
: White
[3] LAMP 2 COLOR
(2nd layer from the top)
R
: Red
Y
: Amber
G
: Green
B
: Blue
W
: White
N
: None (not available when Lamp Layers selected are 2 - 5)
[4] LAMP 3 COLOR
(3rd layer from the top)
R
: Red
Y
: Amber
G
: Green
B
: Blue
W
: White
N
: None (not available when Lamp Layers selected are 3 - 5)
[5] LAMP 4 COLOR
(4th layer from the top)
R
: Red
Y
: Amber
G
: Green
B
: Blue
W
: White
N
: None (not available when Lamp Layers selected are 4 - 5)
[6] LAMP 5 COLOR
R
: Red
Y
: Amber
G
: Green
B
: Blue
W
: White
N
: None (not available when Lamp Layers selected are 5)
* Select "None" option for the layers other than the selected.
MOUNTING
D
: Direct mounting
DESIGN TYPE
1
: Type 1
(refer to outline dimensions)
[7] POWER INPUT
AC Power
M2
: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[8] OPTIONS
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
/C03
: Rubber coating
RELATED PRODUCTS
• LAN cable (model: ITCA)
• Mounting Pole (model: ITPL)
• Mounting Adapter (model: ITAD1)
• PC configurator software (model: ITCFG)
Functions are configurable using the PC Configurator Software.
Downloadable at M-System’s web site.
Access to 192.168.0.1, the factory default setting, to set the device first time.
GENERAL SPECIFICATIONS
Degree of protection
: IP 65, vertical mounting only (bottom connectors excluded)
Connection
Power
:UL1007 AWG20
Network
: RJ-45 Modular Jack
Housing material
: Flame-resistant resin
Lens
: Flame-resistant resin (transparent)
Isolation
: Network to power input to FE1 (Functional Earth)
DIP SW Setting
: Frequency of lamp blinking and buzzing discontinuance, buzzing volume level, output at connection failed and IP address (refer to the instruction manual)
Lamp
: Red, amber, green, blue and white LEDs
on/blinking (approx. 2 Hz, 10 Hz)
Indicator LEDs
: Power, Run
(Refer to the insruction manual)
Buzzing
: Approx. 3.3 kHz
Interval
: continuous/intermittent (approx. 2 Hz, 10 Hz)
COMMUNICATION
Communication Standard
: IEEE 802.3u
Transmission
: 10BASE-T, 100BASE-TX
Baud rate
: 10/100 Mbps (Auto Negotiation function)
Protocol
: Modbus/TCP
Data
: RTU (Binary)
Max. number of socket connections
: 2
Transmission media
: 10BASE-T (STP, Category 5) 100BASE-TX (STP, Category 5e)
Max. length of fieldbus segment
: 100 meters
IP address
: 192.168.0.1 (factory setting);
Selectable with PC Configurator Software
(model: ITCFG)
Port No
.: 502
Ethernet indicator LED
: Link, Link100, COL
INSTALLATION
Power Consumption
•
AC
:
Approx. 7.5 VA at 100 V with max. load
Approx. 10 VA at 200 V with max. load
Approx. 11 VA at 240 V with max. load
•
DC
: Approx. 5 W
Operating temperature
: -10 to +55°C (14 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Atmosphere
: No corrosive gas
Mounting
: Direct mounting
Mounting direction
: Vertical
Weight
: 750 g (1.65 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 1500 V AC @ 1 minute
(network to power to FE1)
STANDARDS & APPROVALS
Refer to the manuals to comply with the standards.
EU conformity
:
EMC Directive
EN 60947-5-1
Low Voltage Directive
EN 60947-5-1
・24 V DC power
Installation Category III
Pollution Degree 3
・100 – 240 V AC power
Installation Category II
Pollution Degree 2
Network to power: Reinforced insulation (300 V)
RoHS Directive
EN 50581
EXTERNAL VIEW
DIMENSIONS unit: mm
MOUNTING REQUIREMENTS unit: mm
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
MG Co., Ltd.