·Some details are not shown. Please refer to specification sheets for all information.

MDC6

DC POWER SUPPLY
(maintenance forecast monitor function)

Functions & Features
• Accepts 100 – 240 V AC and provides regulated 24 V DC output
• Maintenance forecast monitor function

MODEL:MDC6–12024A–M2

ORDERING INFORMATION
• Code number: MDC6-12024A-M2

CAPACITY
120: 120 W

OUTPUT VOLTAGE
24: 24 V DC

MONITOR
A: Maintenance forecast monitor function

POWER INPUT
AC Power
M2: 100 – 240 V AC

GENERAL SPECIFICATIONS
Construction: Front terminal access; terminal cover provided
Connection: M4 screw terminals (torque 1.08 N·m)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (beige); aluminum

SUPPLY OUTPUT
Output voltage: 24 V DC -10/+15 %; adjustable on the front (ripple 2.0 %p-p max.)
Load current: ≤ 5 A
Overload protection: Voltage drop characteristics (105 %)
Overload detecting: 105 % of the rated current

Alarm Output
Transistor: NPN (sink) type; 30 V DC max., 50 mA DC max.
Residual voltage at ON: ≤ 2 V
Leakage current at OFF: ≤ 0.1 mA

INSTALLATION
Power input
AC: Operational voltage range 85 – 264 V AC  50/60 Hz
Operating temperature: 0 to 50°C (32 to 122°F)
Operating humidity: 25 to 85 % RH (non-condensing)
Mounting: DIN rail
Weight: 550 g (1.21 lb)

PERFORMANCE
Temp. coefficient: ±0.05 %/°C (±0.03 %/°F)
Load effect: ≤ 1.5 %
Line voltage effect: ±0.5 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 3000 V AC @ 1 minute
(output to power input)
2000 V AC @ 1 minute (power input to ground)
1000 V AC @ 1 minute (output to ground)

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EN 61204-3 (Class A)
Low Voltage Directive 
  EN 50178
  EN 60950-1
RoHS Directive
  EN 50581
Approval:
  UL 508 (Class 2: per UL 1310)
  CAN/CSA C22.2 No.14
  UL 60950-1 (Class 2)
  CAN/CSA C22.2 No.60950-1
  VDE1060 VDE0805-1+A11

EXTERNAL VIEW

DIMENSIONS unit: mm (inch)

MOUNTING REQUIREMENTS unit: mm (inch)

CONNECTION DIAGRAM

M-System Co., Ltd.