ES-5438 Rev.8
F2PP
Super-mini Signal Conditioners F2 Series
PULSE ISOLATOR
Functions & Features
• Galvanically isolating pulse rate signals
• Input frequency = output frequency
• Various outputs (open collector and voltage pulses)
• High-density mounting
Typical Applications
• Isolating field pulse signals in order to reduce noises
• Changing e.g. dry contact signal to e.g. 5 V signals
MODEL: F2PP–[1][2][3]–R[4]
ORDERING INFORMATION
• Code number: F2PP-[1][2][3]-R[4]
Specify a code from below for each of [1] through [4].
(e.g. F2PP-33N-R/CE/Q)
• Specify the specification for option code /Q
(e.g. /C01)
[1] INPUT
1
: Mechanical contact (max. 30 Hz)
2
: Open collector (max. 10 kHz)
3
: Voltage pulse (max. 10 kHz)
Note: When the output signal is Low frequency open collector, the max. input frequency is 30 Hz.
[2] OUTPUT
1
: Low frequency open collector (max. 30 Hz)
2
: High frequency open collector (max. 10 kHz)
3
: 5 V pulse (max. 10 kHz)
4
: 12 V pulse (max. 10 kHz)
5
: 24 V pulse (max. 10 kHz)
[3] OUTPUT LOGIC
N
: The same as the input
R
: Inverted
POWER INPUT
DC Power
R
: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[4] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N
: Without CE
/CE
: CE marking
Other Options
blank
: none
/Q
: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to our web site.)
/C01
: Silicone coating
/C02
: Polyurethane coating
GENERAL SPECIFICATIONS
Construction
: Stand-alone; terminal access at the front
Connection
: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm
2
, stripped length 7 mm)
Housing material
: Flame-resistant resin (black)
Isolation
: Input to output to power
Frequency range
: Input and output are the same.
Chattering protection
: Filter provided for mechanical contact input
Input pulse sensing
: DC coupled
INPUT SPECIFICATIONS
Excitation
: 12 V DC @30 mA; shortcircuit protection
■
Open Collector
Sensing
: Approx. 12 V DC @ 3 mA
ON/OFF level
: ≤ 200 Ω / 0.6V for ON, ≥ 100 kΩ / 6V for OFF
Low frequency open collector output
Maximum frequency
: 30 Hz
Pulse width time requirement
: 10 msec. min. for ON and OFF
High frequency open collector output
Maximum frequency
: 10 kHz
Pulse width time requirement
: 10 μsec. min. for ON and OFF
■
Mechanical Contact
Maximum frequency
: 30 Hz
Pulse width time requirement
: 10 msec. min. for ON and OFF
Sensing
: Approx. 12 V DC @3 mA
ON/OFF level
: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 6 V for OFF
■
Voltage Pulse
: Square or sine waveforms
Low frequency open collector output
Maximum frequency
: 30 Hz
Pulse width time requirement
: 10 msec. min. for ON and OFF
High frequency open collector output
Maximum frequency
: 10 kHz
Pulse width time requirement
: 10 μsec. min. for ON and OFF
Voltage range
: -30 – +30 V DC
Hi/Lo level
: 2 – 30 V for high level; ≤ 1 V for low level
Input impedance
: 10 kΩ minimum
OUTPUT SPECIFICATIONS
■
Low Frequency Open Collector
:
50 V DC @100 mA (resistive load)
Maximum frequency
: 30 Hz
Timer
: Limits within 75 ±25 msec.
for wider than 75 msec. pulses
ON time for output logic non-inverted
OFF time for output logic inverted
Saturation voltage
: 0.5 V DC
■
High Frequency Open Collector
:
50 V DC @100 mA (resistive load)
Maximum frequency
: 10 kHz
Saturation voltage
: 0.5 V DC
■
Voltage Pulse
Maximum frequency
: 10 kHz
High level
: Rating (5, 12 or 24 V) ±10 %
Low level
: ≤ 0.5V
Load resistance
:
≥ 250 Ω for 5 V
≥ 600 Ω for 12 V
≥ 1200 Ω for 24 V
INSTALLATION
Current consumption
•
DC
: Approx. 80 mA
Operating temperature
: -5 to +55°C (23 to 131°F)
Operating humidity
: 30 to 90 %RH (non-condensing)
Mounting
: DIN rail
Weight
: 150 g (0.33 lb)
PERFORMANCE
Insulation resistance
: ≥ 100 MΩ with 500 V DC
Dielectric strength
: 2000 V AC @1 minute (input to output to power to ground)
STANDARDS & APPROVALS
EU conformity
:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
OUTPUT LOGIC
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM