MDCAT-NC

Lightning Surge Protectors for
Electronics Equipment M-RESTER

LIGHTNING SURGE PROTECTOR FOR CC-Link IE Field Network

Functions & Features
• Recommended for CC-Link IE Field Network
• LAN cable’s shield wire can be floating or grounding by a shortcircuit bar
• DIN rail mounting
• Grounding with M3 screw terminal or via DIN rail

MODEL: MDCAT-NC-5E

ORDERING INFORMATION
•Code number: MDCAT-NC-5E

CABLE CATEGORY
5E: CAT5e

PACKAGE INCLUDES...
LAN cable connected to the protected device        
(Compatible cable with CC-Link IE Field Network, 0.5 meters)

APPLICABLE NETWORK
Applicable network: CC-Link IE Field Network
Applicable cable: Compatible cable wiith CC-Link IE Field Network

GENERAL SPECIFICATIONS
Connection
  Network: RJ-45 modular jack
  Grounding: M3 screw terminal (torque 0.6 N·m)
  or via DIN rail
Screw terminal: Nickel-plated brass
Housing material: Flame-resistant resin (black)

INSTALLATION
Operating temperature: -25 to +85°C (-13 to +185°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Mounting: DIN Rail (TH35-7.5, 1-mm-thick)
When this unit is earthed via a DIN rail, use a steel or copper rail. Oxide film on the surface of an aluminium rail may lower the electric conductivity between this module and the ground.
Weight: 150 g (0.33 lb)

PERFORMANCE
Max. continuous operating voltage (Uc):
 Line to line 1: ±6 V
 Line to line 2: ±58 V
 Line to earth: ±150 V
Voltage protection level (Up):
 Line to line 1: ±15 V (@2 kV, 1.2/50 μsec.) 
 Line to line 2: ±100 V (@2 kV, 1.2/50 μsec.) 
 Line to earth: ±600 V (@4 kV, 1.2/50 μsec.)
Response time:
 Line to line 1: 4 nsec. 
 Line to line 2: 4 nsec.
 Line to earth: 20 nsec.
Leakage current @Uc:
  Line to line 1: 25 μA 
  Line to line 2: 5 μA
  Line to earth: 5 μA
Max. discharge current (Imax)
  Line to line 1: 100 A (8/20 μsec.)
  Line to line 2: 100 A (8/20 μsec.)
  Line to earth: 10 kA (8/20 μsec.)
Nominal current (IN): 1 A
Series resistance: approx. 0 Ω
Note: "Line to line 1" stands for electrodes 1 – 2, 3 – 6, 4 – 5 and 7 – 8, "line to line 2" stands for electrodes 1 · 2 – 3 · 6 and 4 · 5 – 7 · 8 of RJ-45 Modular jack.

STANDARDS & APPROVALS
EU conformity:
EMC Directive 
  EMI EN 61000-6-4
  EMS EN 61000-6-2
RoHS Directive
  EN 50581

Surge protection: IEC 61643-21
 (Categories C1, C2)
Transmission performance:
  TIA/EIA-568-B.2 CAT5e

CONNECTION EXAMPLES
• Install the lightning surge protectors in places where it is considered that lightning surge may enter (where panels/cabinets are greatly separated, such as outdoor wiring).
• The maximum number of surge protectors that can be installed between devices is two (2).  Take into account insertion loss 1 dB per surge protector as a rough indication.
• Refer to "CC-Link IE Field Network Cable Installation Manual” issued by CC-Link Partner Association for details.

DIMENSIONS unit: mm (inch)

SCHEMATIC CIRCUITRY

MG Co., Ltd.